Analysis of Shear Capacity of GFRP Reinforced Beams without Stirrups According to Selected Design Standards
More details
Hide details
Submission date: 2020-09-07
Final revision date: 2020-09-16
Acceptance date: 2020-09-17
Publication date: 2020-12-11
Archives of Civil Engineering 2020;66(4):689-702
KEYWORDS
TOPICS
ABSTRACT
The aim of this paper is a comparative analysis of the experimental test results of twenty T-section beams reinforced with glass fiber reinforced polymer (GFRP) bars without stirrups with predicted values of the shear capacity according to the following design guidelines: draft Eurocode 2, Japanese JSCE, American ACI 440, Italian CNR- DT-203/2006, British BS according to fib Bulletin 40, Canadian CSA-S806-12 and ISIS-M03-07. Standard procedures for FRP reinforced beams based on traditional steel reinforced concrete guidelines. The longitudinal FRP reinforcement has been taken into account by its stiffness reduction related to the steel reinforcement. A basis of this modification is the assumption that the FRP-to-concrete bond behaviour is the same as it is for steel reinforcement. To assess the compatibility of predicted values (Vcal) with the experimental shear forces (Vtest) the safety coefficient η = Vtest / Vcal was used. The results corresponding to values η < 1 indicates overestimation of the shear capacity, but η > 1 means that shear load capacity is underestimated. The most conservative results of the calculated shear capacity are obtained from the ACI 440 standard. In contrast to them the best compatibility of the calculated shear values to the experimental ones indicated British BS standard, fib Bulletin 40 and Canadian CSA-S806-12 standard.